From: Experimental study on airfoil flow separation control via an air-supplement plasma synthetic jet
Parameter | Value/mm |
---|---|
Actuator length A | 20 |
Discharge chamber length a | 14 |
Actuator width B | 10 |
Discharge chamber width b | 5 |
Actuator height H | 25 |
Discharge chamber height h | 15 |
Electrode spacing de | 10 |
Length of check valve outlet ht | 15 |
Diameter of check valve inlet di | 4 |
Diameter of check valve outlet do | 4 |