Skip to main content

Table 2 Flow separation parameters under different actuation states

From: Experimental study on airfoil flow separation control via an air-supplement plasma synthetic jet

Actuation state

SU<0/S0

s/c

Conventional

0.29

0.30

Air-supplement

0.18

0.46